Kunze Fiber Optical FTTH Drop Cable GJYXFCH
Kunze Fiber Optical FTTH Drop Cable Structure:
Kunze Fiber Optical FTTH Drop Cable Application:
Fiber parameters:
| Aihwa. | Items | Unit | Tsanangudzo | |
| G.657A | ||||
| 1 | Mode Field Diameter | 1310nm | μm | 8.6±0.4 |
| 1550nm | μm | 9.6±0.5 | ||
| 2 | Cladding Diameter | μm | 125.0±0.7 | |
| 3 | Cladding Non-Circularity | % | ≤1.0 | |
| 4 | Core-Cladding Eccentricity Error | μm | ≤0.5 | |
| 5 | Coating Diameter | μm | 245±5 | |
| 6 | Coating Non-Circularity | % | ≤6.0 | |
| 7 | Cladding-Coating Eccentricity Error | μm | ≤12.0 | |
| 8 | Cable Cutoff Wavelength | nm | λcc≤1260 | |
| 9 | Attenuation (max.) | 1310nm | dB/km | ≤0.4 |
| 1550nm | dB/km | ≤0.3 | ||
| 10 | Macro-benfloss (1turn.7.5mm radius) | 1550nm | dB | ≤0.5 |
| 1625nm | dB | ≤1.0 | ||
| 11 | Kufambira mberi | kpsi | ≥100 | |
Cable Parameters
| Items | Zvinotsanangurwa | |
| Fiber Count | 2 | |
| Coloured fiber | Dimension | 250±5μm |
| Material | Pro-coated | |
| Color | (bhuruu/tsvuku) | |
| Simba nhengo | Material | FRP |
| Diameter | 0.5MM | |
| Number | 2 | |
| Messenger | Material | Aramid yarn |
| Outer sheath | Material | LSZH |
| Cable dhayamita | ±0.2 | 2.0*5.2 |
| Cable uremu | ±10% | 19.0kg/km |
| Simba nhengo | Kusimbisa chikamu | Phosphating simbi waya |
| Diameter | 1.0MM | |
Mechanical uye Environmental Hunhu
| Items | Unit | Zvinotsanangurwa |
| Crush (Nguva Yakareba) | N/10cm | 680 |
| Crush (Nguva pfupi) | N/10cm | 2200 |
| Min. Bend Radius (Dynamic) | mm | 30D |
| Min. Bend Radius (Static) | mm | 15D |
| Installation Temperature | ℃ | -20+70 |
| Operating Temperature | ℃ | -20+70 |
| Storage Temperature | ℃ | -20+70 |
Mifananidzo yezvigadzirwa:
Mifananidzo yezvigadzirwa:
Nyora meseji yako pano uye titumire kwatiri