Banner peji

1×8 1*8 1:8 Mini chubhu mhando PLC faibha optic splitter

Tsanangudzo Pfupi

• Kurasikirwa kwekuisa pasi, kurasikirwa kukuru kwekudzoka

• Yakanakisa Tembiricha kugadzikana

• Kudzokorora kwakanaka uye kuchinjana

• Excellent mechanical kutsungirira

• Yakasimba kurapa nguva uye tembiricha kutonga

• Kuomarara kuyerwa zviyero uye nzira dzemhando

• Kuchengetedza kwezvakatipoteredza (ROHS Compliance)

• Iyo fiber optical patch tambo inogona kugadzirwa zvinoenderana nezvinodiwa nevatengi (Customized Connector/ Length/ package…)


Product Detail

Product Tags

Product Description:

Iyo PLC fiber optic splitter yakavakirwa pane planar Lightwave wedunhu tekinoroji uye yakanyatso kurongedza maitiro, inogona kupatsanura imwechete / mbiri mbiri optical input (s) mune akawanda optical kubuda zvakafanana uye inoratidzwa 1 * N kana 2 * N.

PLC fiber optic splitter imhando ye optical power management mudziyo unogadzirwa uchishandisa silica optical waveguide tekinoroji.

Iyo ine saizi diki, kuvimbika kwepamusoro, yakafara yeavelength renji uye yakanaka chiteshi-kune-chiteshi kufanana, uye inoshandiswa zvakanyanya muPON network kuona optical chiratidzo chemagetsi kupatsanura.

PLC fiber optic splitter inopa yepamusoro optical performance, yakanyanya kugadzikana uye kuvimbika kwepamusoro, inosangana nezvinodiwa zvakasiyana zvekushandisa munzvimbo dzakasiyana.

1x8 PLC fiber optic splitter inouya ne 1 yekupinda uye 8 kubuda. Kupinza uye kubuda tambo kureba kunogona kuva 0.6m, 1.0m, 1.5m kana customized. Inowanikwa nemhando dzakawanda dzekubatanidza dzakadai se: SC/UPC, SC/APC, LC/UPC, LC/APC,

1x8 PLC fiber optic splitter inoshandiswa zvakafara mu8 ports rack gomo bhokisi rekugovera furemu, kana zvakare yakafara kushandiswa mumasere ekunze fiber optic bhokisi rekugovera.

Application:

FTTX network

PON network

CATV links

Data Kukurukurirana

Telecommunication

Optical Signal Distribution

Feature:

Kurasikirwa kwekuisa pasi, kurasikirwa kukuru kwekudzoka

Yakanakisa Tembiricha kugadzikana

Kudzokorora kwakanaka uye kuchinjana

Yakanakisa mechanical endurance

Yakasimba kurapa nguva uye tembiricha kutonga

Yakasimba yekuyedza zviyero uye nzira dzemhando

Kuchengetedzwa kwezvakatipoteredza (ROHS Compliance)

Iyo fiber optical chigamba tambo inogona kugadziridzwa zvinoenderana nevatengi 'zvinodikanwa zvinodiwa (Customized Connector/ Length/ package...)

Parameter:

Port Configuration 1*8
Insertion Loss (dB) Max 10.6
Kurasika Uniformity (dB) 1.0
PDL(dB) 0.25
Wavelength Dependent Loss(dB) 0.3
Temp. Dependent Loss (-40~85 ) (dB) 0.4

Ongorora: Iyo iri pamusoro paramende ndeye splitter isina chinongedzo.

Port Configuration 1*8
Insertion Loss (dB) Max 10.8
Kurasika Uniformity (dB) 1.0
PDL(dB) 0.2
Wavelength Dependent Loss (dB) 0.3
Temp. Dependent Loss (-40~85°C ) (dB) 0.4

Ongorora: Iyo iri pamusoro paramende ndeye splitter ine connector.

Absolute Maximum Ratings

Parameter

Symbol

Min.

Typical

Max.

Unit

Storage Temperature

TS

-40

 

+85

°C

Case Operating Temperature SFP+ -10G-LR

TA

0

 

70

°C

SFP+ -10G-LR-I

-40

 

+85

°C

Maximum Supply Voltage

Vcc

-0.5

 

4

V

Relative Humidity

RH

0

 

85

%

Electrical Characteristics (TOP = 0 kusvika 70 °C, VCC = 3.135 kusvika 3.465 Volts)

Parameter

Symbol

Min.

Typical

Max.

Unit

Cherechedza

Supply Voltage

Vcc

3.135

 

3.465

V

 

Supply Current

Icc

 

 

430

mA

 

Kushandisa Simba

P

 

 

1.5

W

 

Transmitter Chikamu:
Input differential impedance

Rin

 

100

 

Ω

1

Tx Input Imwe Yakapera DC Voltage Tolerance (Ref VeeT)

V

-0.3

 

4

V

 

Differential input voltage swing

Vin, pp

180

 

700

mV

2

Transmit Disable Voltage

VD

2

 

Vcc

V

3

Transmit Enable Voltage

VEN

Vee

 

Vee+0.8

V

 

Receiver Chikamu:
Imwe Yakapera Kubuda Voltage Kushivirira

V

-0.3

 

4

V

 

Rx Output Diff Voltage

Vo

300

 

850

mV

 

Rx Kubuda Kusimuka uye Kudonha Nguva

Tr/Tf

30

 

 

ps

4

LOS Mhosva

VLOS kukanganisa

2

 

VccHOST

V

5

LOS Normal

VLOS zvakajairwa

Vee

 

Vee+0.8

V

5

Notes:1. Yakabatanidzwa zvakananga kuTX data yekupinza pini. AC kubatanidza kubva mapini mulaser driver IC.
2. Per SFF-8431 Rev 3.0.
3. Mu100 ohms kusiyana kwekugumisa.
4. 20%~80%.
5. LOS ndiyo yakazaruka muunganidzi yakabuda. Inofanirwa kudhonzwa ne4.7k - 10kΩ pane iyo host board. Kushanda kwakajairika ndeye logic 0; kurasikirwa kwechiratidzo ndiko logic 1. Maximum pull-up voltage is 5.5V.

Optical Parameters (TOP = 0 kusvika 70 ° C, VCC = 3.135 kusvika 3.465 Volts)

Parameter

Symbol

Min.

Typical

Max.

Unit

Cherechedza

Transmitter Chikamu:
Center Wavelength

λt

1290

1310

1330

nm

 

spectral width

λ

 

 

1

nm

 

Avhareji Optical Power

Pavg

-6

 

0

dBm

1

Optical Power OMA

Poma

-5.2

 

 

dBm

 

Laser Off Power

Poff

 

 

-30

dBm

 

Extinction Ratio

ER

3.5

 

 

dB

 

Transmitter Dispersion Chirango

TDP

 

 

3.2

dB

2

Relative Intensity Noise

Rin

 

 

-128

dB/Hz

3

Optical Return Loss Tolerance

 

20

 

 

dB

 

Receiver Chikamu:
Center Wavelength

λr

1260

 

1355

nm

 

Receiver Sensitivity

Sen

 

 

-14.5

dBm

4

Stressed Sensitivity (OMA)

SenST

 

 

-10.3

dBm

4

Los Assert

LOSA

-25

 

-

dBm

 

Los Dessert

LOSD

 

 

-15

dBm

 

Los Hysteresis

LOSH

0.5

 

 

dB

 

Overload

Sat

0

 

 

dBm

5

Receiver Reflectance

Rrx

 

 

-12

dB

 

Notes:1. Avhareji yenhamba dzesimba dzinodzidzisa chete, paIEEE802.3ae.
2. Chimiro cheTWDP chinoda kuti bhodhi rekugamuchira rive SFF-8431inoenderana. TWDP inoverengwa pachishandiswa kodhi yeMatlab yakapihwa muchikamu 68.6.6.2 cheIEEE802.3ae.
3. 12dB kuratidza.
4. Mamiriro ekusimbiswa kwekugamuchira miedzo paIEEE802.3ae. Kuongororwa kweCSRS kunoda kuti bhodhi rekutambira rive SFF-8431 inoenderana.
5. Receiver overload inotsanangurwa muOMA uye pasi pemamiriro ezvinhu akaipisisa akasimbiswa.

Nguva Yemaitiro

Parameter

Symbol

Min.

Typical

Max.

Unit

TX_Disable Assert Nguva

t_off

 

 

10

us

TX_Disable Negate Nguva

t_on

 

 

1

ms

Nguva Yekutanga Inosanganisa Reset yeTX_FAULT

t_int

 

 

300

ms

TX_FAULT kubva kuFault kuenda kuAssertion

t_fault

 

 

100

us

TX_Disable Nguva Yekutanga Reset

t_reset

10

 

 

us

Receiver Kurasikirwa kweSignal Assert Time

TA,RX_LOS

 

 

100

us

Receiver Kurasikirwa kweSignal Deassert Nguva

Td,RX_LOS

 

 

100

us

Rate-Sarudza Chage Nguva

t_ratesel

 

 

10

us

Serial ID Clock Nguva

t_serial-clock

 

 

100

kHz

Pin Basa

Dhiagiramu yeHost Board Connector Block Pin Nhamba uye Zita

chigadzirwa3

Pin Function Definitions

PIN

Zita

Function

Notes

1

VeeT Module transmitter pasi

1

2

Tx Fault Module transmitter kukanganisa

2

3

Tx Disable Transmitter Disable; Inodzima transmitter laser kubuda

3

4

SDL 2 waya serial interface data yekuisa / kubuda (SDA)

 

5

SCL 2 waya serial interface wachi yekupinda (SCL)

 

6

MOD-ABS Module Kusipo, batanidza kuVeeR kana VeeT mune module

2

7

RS0 Rate sarudza0, sarudzo dzora SFP + inogamuchira. Kana yakakwira, dhizaini yekupinza data> 4.5Gb/ s; kana yakaderera, yekuisa data rate <= 4.5Gb/s

 

8

LOS Receiver Kurasika Kwechiratidzo Chiratidzo

4

9

RS1 Rate sarudza0, sarudzo dzora SFP + transmitter. Kana yakakwira, dhizaini yekupinza data> 4.5Gb/s; kana yakaderera, yekuisa data rate <= 4.5Gb/s

 

10

VeeR Module receiver ground

1

11

VeeR Module receiver ground

1

12

RD- Receiver inverted data kunze kuiswa

 

13

RD+ Receiver isina-inverted data kunze kuiswa

 

14

VeeR Module receiver ground

1

15

VccR Module inogamuchira 3.3V inopa

 

16

VccT Module transmitter 3.3V kupa

 

17

VeeT Module transmitter pasi

1

18

TD+ Transmitter inverted data kunze yakaiswa

 

19

TD- Transmitter isina-inverted data kunze kuiswa

 

20

VeeT Module transmitter pasi

1

Cherechedza:1. Iyo module yepasi pini ichave yakasarudzika kubva kune module kesi.
2. Pini iyi ipikiri yekuunganidzira yakavhurika/inoburitsa uye ichadhonzwa kumusoro ne 4.7K-10Kohms kuenda kuHost_Vcc pabhodhi rekutambira.
3. Pini iyi ichadhonzwa ne4.7K-10Kohms kuVccT mumodule.
4. Pini iyi ipini yakavhurika yekuunganidzira/dhiraivha uye ichadhonzwa kumusoro ne 4.7K-10Kohms kuenda kuHost_Vcc pabhodhi rekutambira.

SFP Module EEPROM Ruzivo uye manejimendi

Iyo SFP modules inoshandisa iyo 2-waya serial yekutaurirana protocol sezvinotsanangurwa muSFP -8472. Iyo serial ID ruzivo rweSFP modules uye Digital Diagnostic Monitor paramita inogona kuwanikwa kuburikidza neI.2C interface pakero A0h uye A2h. Chiyeuchidzo chinoiswa muTebhura 1. Ruzivo rwechitupa rwakadzama (A0h) rwakanyorwa muTebhu 2., uye tiye DDM tsanangudzo pakero A2h. Kuti uwane rumwe ruzivo rwemepu yekurangarira uye byte tsananguro, ndapota tarisa kune iyo SFF-8472, "Digital Diagnostic Monitoring Interface yeOptical Transceivers". Iyo DDM paramita yakagadziriswa mukati.

Tafura1. Digital Diagnostic Memory Map (Specific Data Field Descriptions).

chigadzirwa1

Tafura 2- EEPROM Serial ID Memory Zviri mukati (A0h)

Data Kero

Urefu

(Byte)

Zita re

Urefu

Tsanangudzo uye Zviri mukati

Base ID Minda

0

1

Identifier

Mhando yeSerial transceiver (03h=SFP)

1

1

Reserved

Yakawedzerwa identifier yemhando serial transceiver (04h)

2

1

Connector

Kodhi ye optical connector type (07=LC)

3-10

8

Transceiver

10G Base-LR

11

1

Encoding

64B/66B

12

1

BR, Nominal

Nominal baud rate, unit ye100Mbps

13-14

2

Reserved

(0000h)

15

1

Kureba (9um)

Kureba kwekubatanidza kunotsigirwa 9/125um fiber, zvikamu zve100m

16

1

Kureba(50um)

Kureba kwekubatanidza kunotsigirwa 50/125um fiber, zvikamu zve 10m

17

1

Kureba(62.5um)

Kureba kwekubatanidza kunotsigirwa 62.5 / 125um fiber, zvikamu zve 10m

18

1

Urefu(Mhangura)

Kureba kwekubatanidza kunotsigirwa nemhangura, mayunitsi emamita

19

1

Reserved

 

20-35

16

Zita remutengesi

SFP zita remutengesi:VIP Fiber

36

1

Reserved

 

37-39

3

Mutengesi OUI

SFP transceiver mutengesi OUI ID

40-55

16

Mutengesi PN

Chikamu Nhamba: “SFP+ -10G-LR” (ASCII)

56-59

4

Mutengesi rev

Revision level yechikamu nhamba

60-62

3

Reserved

 

63

1

CCID

Inonyanya kukosha byte yehuwandu hwe data mukero 0-62
Yakawedzerwa ID Minda

64-65

2

Option

Inoratidza kuti ndeapi masaini eSFP anoitwa

(001Ah = LOS, TX_FAULT, TX_DISABLE zvese zvinotsigirwa)

66

1

BR, max

Upper bit rate margin, zvikamu zve%

67

1

BR, min

Yakaderera bit rate margin, zvikamu zve%

68-83

16

Mutengesi SN

Serial nhamba (ASCII)

84-91

8

Date code

VIP Fiber's Manufacturing date code

92-94

3

Reserved

 

95

1

CCEX

Tarisa kodhi yeakawedzera ID Minda (kero 64 kusvika 94)
Mutengesi Yakananga ID Minda

96-127

32

Inoverengwa

VIP Fiberzuva chairo, verenga chete

128-255

128

Reserved

Yakachengeterwa SFF-8079

Digital Diagnostic Monitor Hunhu

Data Kero

Parameter

Kururama

Unit

96-97 Transceiver Internal Temperature ±3.0 °C
100-101 Laser Bias Yazvino ±10 %
100-101 Tx Output Power ±3.0 dBm
100-101 Rx Input Simba ±3.0 dBm
100-101 VCC3 Internal Supply Voltage ±3.0 %

Regulatory Compliance

TheSFP+ -10G-LR inopindirana neInternational Electromagnetic Compatibility (EMC) uye yepasirese kuchengetedza zvinodiwa uye zviyero (ona zvakadzama muTafura inotevera).

Electrostatic Discharge

(ESD) kuMagetsi Pini

MIL-STD-883E

Nzira 3015.7

Kirasi 1(>1000 V)
Electrostatic Discharge (ESD)

kuDuplex LC Receptacle

IEC 61000-4-2

GR-1089-CORE

Inopindirana nemitemo
Electromagnetic

Kupindira (EMI)

FCC Chikamu 15 Kirasi B

EN55022 Kirasi B (CISPR 22B)

VCCI Kirasi B

Inopindirana nemitemo
Laser Eye Kuchengetedza FDA 21CFR 1040.10 uye 1040.11

EN60950, EN (IEC) 60825-1,2

Inoenderana neKirasi 1 laser

chigadzirwa.

Recommended Circuit

chigadzirwa4

Yakakurudzirwa Host Board Power Supply Circuit

chigadzirwa5

Inokurudzirwa High-speed Interface Circuit

Technical Data:

Fiber urefu 1.0mkana Customized
Connector Type SC,LC,

FC

kana Customized

Optical Fiber Type G652DG657A1

kana Customized

Kutungamira (dB) Min * 55
Dzorera Kurasika (dB) Min * 55 (50)
Kubata Simba (mW) 300
Kushanda Wavelength (nm) 1260 ~ 1650
Kushanda Tembiricha(°C) -40 ~ +85
Kuchengetera Tembiricha(°C) -40 ~ +85

Mutsara wekugadzira:

product_1

  • Zvakapfuura:
  • Zvinotevera:

  • Nyora meseji yako pano uye titumire kwatiri