10Gb/s SFP+ Active Optical Cable
Features
+ Tsigira 10GBASE-SR/10G Fiber Channel application
+ Inoenderana neSFP+ Magetsi MSA SFF-8431
+ Inoenderana neSFP + Mechanical MSA SFF-8432
+ Multi rate inosvika 11.3Gbps
+ Kuendesa kure kusvika ku150m (OM3)
+ + 3.3V simba rimwechete
+ Yakaderera simba rekushandisa
+ Kushanda kesi tembiricha: Zvekutengesa: 0°C kusvika +70 °C
+ RoHS inoenderana
+ Dziviriro yepassword yeA0h uye A2h
Applications
+ 10GBASE-SR pa10.31Gbps
+ InfiniBand QDR, SDR, DDR
+ Zvimwe zvinongedzo zvemaziso
Electrical Characteristics
| Parameter | Symbol | Min. | Typ. | Max. | Units | Notes | |
| Transmitter | |||||||
| Differential Data Input Swing | Vmuri, PP | 200 | - | 1600 | mVPP |
| |
| Input Differential Impedance | ZIN | 90 | 100 | 110 | Ω |
| |
| Tx_Fault | Normal Operation | VOL | 0 | - | 0.8 | V |
|
| Transmitter Fault | VOH | 2.0 | - | VCC | V |
| |
| Tx_Disable | Normal Operation | VIL | 0 | - | 0.8 | V |
|
| Laser Disable | VIH | 2.0 | - | VCC+0.3 | V |
| |
| Receiver | |||||||
| Differential Date Output | Vkunze | 370 | - | 1600 | mV |
| |
| Output Differential Impedance | ZD | 90 | 100 | 110 | Ω |
| |
| Rx_LOS | Normal Operation | VOL | 0 | - | 0.8 | V |
|
| Lose Signal | VoH | 2.0 | - | VCC | V | ||
Optical Characteristics
| Parameter | Symbol | Unit | Min | Typ | Max | Notes |
| Optical transmitter Hunhu | ||||||
| Data Rate | DR | Gbps | 9.953 | 10.3125 | 11.3 |
|
| Center Wavelength Range | λc | nm | 820 | 850 | 880 |
|
| Laser Off Power | Poff | dBm | - | - | -45 |
|
| Tanga Optical Power | P0 | dBm | -6.0 |
|
| 1 |
| Extinction Ratio | ER | dB | 3 | - | - |
|
| Spectral Width (RMS) | RMS | nm | - |
| 0.45 |
|
| Optical Receiver Hunhu | ||||||
| Data Rate | DR | Gbps | 9.953 | 10.3125 | 11.3 |
|
| Bit Error Rate | BER | dBm | - | - | E-12 | 2 |
| Overload Input Optical Power | PIN | dBm | 2.4 | - | - | 2 |
| Center Wavelength Range | λc | nm | 820 | - | 880 |
|
| Receiver Sensitivity muAvhareji Simba | Sen | dBm | - | - | -9.9 | 3 |
| Los Assert | LosA | dBm | -26 | - | - |
|
| Los De-Assert | LosD | dBm | - | - | -12 |
|
| Los Hysteresis | LosH | dB | 0.5 | - | - | |
Cherechedza:
- Yakabatanidzwa mu50/125 MMF.
- Yakayerwa nePRBS 231-1 bvunzo patani @10.3125Gbps.BER=10E-12
Optical Characteristics
| Parameter | Value | Units |
| Diameter | 3 | mm |
| Minimum bend radius | 30 | mm |
| Kureba kushivirira | Kureba <1 m: +5 /-0 | cm |
| 1 m ≤ kureba ≤ 4.5 m: +15 / -0 | cm | |
| 5 m ≤kureba ≤ 14.5 m: +30 / -0 | cm | |
| Kureba≥15.0 m +2% / -0 | m | |
| Cable color | Aqua (OM3); Orange (OM2) | |