Banner peji

KCO-SFP+-10G-ER 10Gb/s 1550nm SFP+ 40kmTransceiver

Tsanangudzo Pfupi

KCO SFP+ 10G ER ndiyo chiyero che 10 Gigabit Ethernet pamusoro pefiber optic cables, yakanyatsogadzirirwa kuendesa kure kure.

Inobvumira kuendesa data kusvika ku40 km pamusoro pe-single-mode fiber (SMF) pane wavelength ye1550nm.

KCO SFP + 10G ER fiber optic modules, inowanzoitwa seSFP + transceivers, inoshandiswa mumhando dzakasiyana-siyana apo kureba kwekusvika kunodiwa, zvakadai sekubatanidza zvivako pamusasa mukuru kana mukati meguta guru.


Product Detail

Product Tags

KCO-SFP+-10G-ER

+ KCO SFP+ 10G ER ndiyo chiyero che10 Gigabit Ethernet pamusoro pefiber optic cables, yakanyatsogadzirirwa kutapurirana kure-kure.

+ Inobvumira kuendesa data kusvika ku40 km pamusoro pe-single-mode fiber (SMF) pane wavelength ye1550nm.

+ KCO SFP + 10G ER fiber optic modules, inowanzoitwa seSFP + transceivers, inoshandiswa mumhando dzakasiyana-siyana apo kureba kwekusvika kunodiwa, zvakadai sekubatanidza zvivako pamusasa mukuru kana mukati meguta guru.

Product Features

+ Kusvikira ku11.1Gbps Data Links

+ Kusvikira ku40km kutapurirana paSMF

+ EML transmitter uye PIN inogamuchira

+ Metal yakavharirwa, kune yakaderera EMI

+ 2-waya interface ine yakabatanidzwa Digital Diagnostic yekutarisa

+ Hot-pluggable SFP + tsoka

+ Tsanangudzo inoenderana neSFF 8472

+ Inoenderana neSFP + MSA ine LC yekubatanidza

+ Imwe 3.3V magetsi ekupa

+ Case inoshanda tembiricha:0°C kusvika 70°C

+ Kubvisa simba <1.5 W

Applications

+ 10GBASE-ER/EW & 10G Ethernet

Standard

+ Inoenderana neSFF-8431

+ Inoenderana neSFF 8472

+ RoHS Inoenderana.

Absolute Maximum Ratings

Parameter

Symbol

Min.

Typ.

Max.

Unit

Storage Temperature

Ts

-40

-

85

ºC

Relative Humidity

RH

5

-

95

%

Power Supply Voltage

VCC

-0.3

-

4

V

Signal Input Voltage

Vcc-0.3

-

Vcc+0.3

V

Yakakurudzirwa Operating Conditions

Parameter

Symbol

Min.

Typ.

Max.

Unit

Cherechedza

Case Operating Temperature

Tcase

0

-

70

ºC

Pasina kuyerera kwemhepo

Power Supply Voltage

VCC

3.14

3.3

3.47

V

Power Supply Current

ICC

-

450

mA

Data Rate

BR

10.3125

Gbps

Transmission Distance

TD

-

40

km

Coupled fiber

Single mode fiber

9/125um SMF

Optical Characteristics

Parameter

Symbol

Min.

Typ.

Max.

Unit

Cherechedza

Transmitter

Avhareji Yakatangwa Simba

PO

-1

+3

dBm

Cherechedza (1)

Extinction Ratio

ER

6

dB

Center Wavelength

λc

1530

1550

1565

nm

Spectrum Band Width (RMS)

σ

1.0

nm

SMSR

30

dB

Transmitter OFF Output Power

POff

-30

dBm

Transmitter uye Dispersion Chirango

TDP

3.0

dB

Output Eye Mask

Inoenderana neIEEE 802.3ae

Receiver

Input Optical Wavelength

λ

1270

1610

nm

Receiver Sensitivity

Psen

-15.8

dBm

Cherechedza (2)

Input Saturation Power (Overload)

Psat

0.5

dBm

LOS Detect -Assert Power

PA

-28

dBm

LOS Detect - Deassert Simba

PD

-19

dBm

LOS Detect Hysteresis

PHYS

0.5

dB

Cherechedza:
1.Yakatangwa simba (avg.) isimba rakasanganiswa kuita imwe modhi faibha ine master connector.(Pamberi peHupenyu)
2.Yakayerwa nechiratidzo chekuyedza kuenderana cheBER = 10^–12.@10.3125Gbps, PRBS=2^31-1,NRZ

Electrical Characteristics

Parameter

Symbol

Min

Typ

Max

Unit

CHERECHEDZA

Supply Voltage

Vcc

3.14

3.3

3.46

V

Supply Current

Icc

450

mA

Transmitter

Input differential impedance

Rin

100

Ω

1

Single ended data input swing

Vin, pp

180

700

mV

Transmit Disable Voltage

VD

Vcc–1.3

Vcc

V

Transmit Enable Voltage

VEN

Vee

Vee+ 0.8

V

2

Tumira Disable Assert Nguva

10

us

Receiver

Differential data output swing

Vout,pp

300

850

mV

3

Kubuda kwedata kusimuka nguva

tr

28

ps

4

Data kubuda nguva yekudonha

tf

28

ps

4

LOS Mhosva

VLOS kukanganisa

Vcc–1.3

VccHOST

V

5

LOS Normal

VLOS zvakajairika

Vee

Vee+0.8

V

5

Kurambwa Kwemagetsi

PSR

100

mVpp

6

Notes:

  1. Yakabatanidzwa zvakananga kune TX data yekupinza pini. AC yakabatanidzwa ipapo.
  2. Kana kuvhura dunhu.
  3. Mu100 ohms kusiyanisa kugumisa.
  4. 20 - 80%.
  5. Kurasika Kwechiratidzo ndeye LVTTL. Logic 0 inoratidza kushanda kwakajairika; logic 1 inoratidza kuti hapana chiratidzo chaonekwa.

Receiver senitivity inoenderana nemagetsi ekupa sinusoidal modulation ye20 Hz kusvika 1.5 MHz kusvika kune yakatsanangurwa kukosha yakashandiswa kuburikidza neinokurudzirwa magetsi ekupa kusefa network.

Pin Tsanangudzo

KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40kmTransceiver (1)

Pin

Symbol

Zita/Tsanangudzo

CHERECHEDZA

1

VEET

Transmitter Ground (Yakajairika neReceiver Ground)

1

2

TMHOSVA

Transmitter Fault.

2

3

TDIS

Transmitter Disable. Laser kubuda yakaremara kumusoro kana kuvhurika.

3

4

SDA

2-waya Serial Interface Data Line

4

5

SCL

2-waya Serial Interface Clock Line

4

6

MOD_ABS

Module Absent. Yakaiswa mukati memodule

4

7

RS0

Rate Sarudza 0

5

8

LOS

Kurasika kweChiratidzo chiratidzo. Logic 0 inoratidza kushanda kwakajairika.

6

9

RS1

Hapana kubatana kunodiwa

1

10

VEER

Receiver Ground (Yakajairika neTransmitter Ground)

1

11

VEER

Receiver Ground (Yakajairika neTransmitter Ground)

1

12

RD-

Receiver Yakapinza DATA kunze. AC Coupled

13

RD+

Receiver Isina-inverted DATA kunze. AC Coupled

14

VEER

Receiver Ground (Yakajairika neTransmitter Ground)

1

15

VCCR

Receiver Power Supply

16

VCCT

Transmitter Power Supply

17

VEET

Transmitter Ground (Yakajairika neReceiver Ground)

1

18

TD+

Transmitter Isina-Inverted DATA in. AC Coupled.

19

TD-

Transmitter Inverted DATA in. AC Coupled.

20

VEET

Transmitter Ground (Yakajairika neReceiver Ground)

1

Notes:

  1. Circuit ground rakaparadzaniswa nechomukati kubva chassis pasi.
  2. TMHOSVAndeye yakavhurika muunganidzi / yekudonhedza yakabuda, iyo inofanirwa kudhonzwa kumusoro ne4.7k - 10k Ohms resistor pane iyo host board kana yakaitirwa kushandiswa. Dhonza voltage inofanira kunge iri pakati pe2.0V kusvika kuVcc + 0.3VA yakakwira kuburitsa kunoratidza kukanganisa kwekutapurirana kunokonzerwa neTX bias yazvino kana iyo TX yekubuda simba inodarika preset alarm zvikumbaridzo. Kubuda kwakaderera kunoratidza kushanda kwakajairika. Munzvimbo yakaderera, chinobuda chinodhonzwa ku <0.8V.
  3. Laser kubuda yakadzimwa paTDIS> 2.0V kana kuvhura, inogoneswa paTDIS<0.8V.
  4. Inofanirwa kudhonzwa ne4.7kΩ- ​​10kΩ host board kune voltage pakati pe2.0V ne3.6V. MOD_ABS inodhonza mutsara wakaderera kuratidza module yabatanidzwa.
  5. Mukati yakadhonzwa pasi paSFF-8431 Rev 4.1.
  6. LOS ndeye yakavhurika yekuunganidza yakabuda. Inofanirwa kudhonzwa ne4.7kΩ - 10kΩ pabhodhi rekutambira kune voltage iri pakati pe2.0V ne3.6V. Logic 0 inoratidza kushanda kwakajairika; logic 1 inoratidza kurasikirwa kwechiratidzo.

Digital Diagnostic Mabasa

OP-SFP + -ER transceivers inotsigira 2-waya serial communication protocol sezvinotsanangurwa muSFP + MSA.

Iyo yakajairwa SFP serial ID inopa ruzivo rwekuzivikanwa iyo inotsanangura kugona kweiyo transceiver, yakajairwa interfaces, mugadziri, uye rumwe ruzivo.

Pamusoro pezvo, SFP + transceivers inopa yakasarudzika yakagadziridzwa yedhijitari diagnostic monitoring interface, iyo inobvumira chaiyo-nguva yekuwana kune mudziyo unoshanda paramita senge transceiver tembiricha, laser bias ikozvino, transmitted optical simba, yakagamuchira optical simba uye transceiver supply voltage. Iyo zvakare inotsanangura yakaomesesa sisitimu yealarm uye nyevero mireza, iyo inozivisa vashandisi-yekupedzisira kana mamwe maparamendi ekushanda ari kunze kwefekitori set yakajairika renji.

SFP MSA inotsanangura 256-byte memory mepu muEEPROM inosvikika pamusoro pe 2-waya serial interface pa8 bit address 1010000X (A0h) .The digital diagnostic monitoring interface inoshandisa 8 bit address 1010001X (A2h), saka iyo yakatanga kutsanangurwa inoramba isina kuchinjwa serial ID mepu.

Ruzivo rwekushandisa uye rwekuongorora runotariswa uye rwunotaurwa neDigital Diagnostics Transceiver Controller (DDTC) mukati meiyo transceiver, iyo inowanikwa kuburikidza ne2-waya serial interface. Kana iyo serial protocol yaitwa, serial wachi chiratidzo (SCL, Mod Def 1) inogadzirwa nemugamuchiri. Iyo yakanaka yekumucheto inovhara data muSFP transceiver mune izvo zvikamu zveE2PROM zvisina kunyorwa-dzivirirwa. Iyo yakaipa kumucheto inovhara data kubva kune SFP transceiver. Iyo serial data chiratidzo (SDA, Mod Def 2) ndeye bi-directional kune serial data kutamiswa. Iyo saiti inoshandisa SDA pamwe chete neSCL kumaka kutanga uye kupera kwe serial protocol activation. Idzo ndangariro dzakarongwa senhevedzano ye8-bit data mazwi anogona kutaridzirwa ega kana kutevedzana.

Yakakurudzirwa Interface Circuit

KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40kmTransceiver (2)

Rondedzera Dimensions

KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40kmTransceiver (3)

Regulatory Compliance

Feature

Reference

Performance

Electrostatic discharge (ESD)

IEC/EN 61000-4-2

Inopindirana nemitemo

Electromagnetic Interference (EMI)

FCC Chikamu 15 Kirasi B EN 55022 Kirasi B (CISPR 22A)

Inopindirana nemitemo

Laser Eye Kuchengetedza

FDA 21CFR 1040.10, 1040.11 IEC/EN 60825-1, 2

Kirasi 1 laser chigadzirwa

ROHS

2002/95/EC

Inopindirana nemitemo

EMC

EN61000-3

Inopindirana nemitemo

Appendix A. Document Revision

Shanduro Nha.

Date

Tsanangudzo

1.0

2010-09-01

Preliminary datasheet

2.0

2011-09-10

Gadziridza fomati uye logo yekambani

3.0

2012-08-03

Gadziridza simba rekuti -1~4 kusvika -1~3


  • Zvakapfuura:
  • Zvinotevera:

  • Nyora meseji yako pano uye titumire kwatiri